NOTE: Applies to 2, 4 and 7 pin high-voltage connectors.
STEP 1:
Use Corona-Resistant High-Voltage Wire
15KV Rating
AWG #16 Max. Conductor
.20 Max. Wire Insulation Diameter
Strip insulation back 1/4″ from the end of all cables and pre-tin the conductor.
Apply socket to the conductor by pushing it up against the insulation and solder onto the conductor. Clean SURFACE “A” (2 inches minimum) thoroughly with alcohol and apply a thin coating of “RTV-108” or equivalent.
Clean the inner surfaces of the housing and strain relief thoroughly with alcohol. Slide the strain relief and the cap over cables.
Insert cable/socket assemblies in cavities of the housing until they lock into place, and moisture cure the “RTV-108” at 100% humidity and 140° F for 1 hour. This will seal cavities before final potting. Slip cap over housing and cement strain relief to the housing.
Once the strain relief is attached, pot the strain relief and housing with Hysol #4215 or equivalent by pouring through the strain relief. (Potting mixture to be 100 parts of Hysol #4215 to 15 parts Hardener #3561)