Skip To Content

Cable/Plug Attachment – Coaxial/Triax | MHV

Cable/Plug Attachment - Coaxial/Triax | MHV

Coaxial cables: RG-59/U


STEP 1:
Cable/Plug Attachment - Coaxial/Triax | MHV

Slide nut, washer and gasket over jacket, and cut off jacket 19/32″ from end of cable as shown.

STEP 2:
Cable/Plug Attachment - Coaxial/Triax | MHV

Comb out braid, pull braid wires forward and taper toward conductor.

STEP 3:
Cable/Plug Attachment - Coaxial/Triax | MHV

Place clamp over braid and push back against cable jacket. Fold back braid wires as shown, trim to proper length and evenly form over clamp as shown. Cut dielectric to 1/8″ dimension as shown. Tin exposed conductor using minimum amount of heat.

STEP 4:
Cable/Plug Attachment - Coaxial/Triax | MHV

Solder contact to conductor. Remove excess flux and solder from outside of contact.

STEP 5:
Cable/Plug Attachment - Coaxial/Triax | MHV

Insert prepared cable termination into plug body. Tighten nut moderately, holding plug body stationary.